Hello,
I’m developing a MQTT client using the C version 1.0.3 for a linux platform. I noticed that my broker does not receive any PINGREQS from the client so the broker disconnects the client. Does the client need to manually send the message, or is there a way to ‘turn on’ this feature that I’ve missed.
This is the printout from my broker.
20160218 115220.284152: C 20.27 to S: Connects(DUP=False, QoS=0, Retain=False, ProtocolName=MQTT, ProtocolVersion=4, CleanSession=True, WillFlag=False, KeepAliveTimer=10, ClientId=20.27, usernameFlag=False, passwordFlag=False)
Hex: ['0x10', '0x11', '0x0', '0x4', '0x4d', '0x51', '0x54', '0x54', '0x4', '0x2', '0x0', '0xa', '0x0', '0x5', '0x32', '0x30', '0x2e', '0x32', '0x37']
String: b'\x10\x11\x00\x04MQTT\x04\x02\x00\n\x00\x0520..27'
20160218 115220.287514: S to C 20.27: Connacks(DUP=False, QoS=0, Retain=False, Session present=False, ReturnCode=0)
Hex: ['0x20', '0x2', '0x0', '0x0']
String: b' \x02\x00\x00'
20160218 115235.314276 client 20.27 connection closing
Kind Regards,
Joe Harte