oleControlSiteObject.deactivateInPlaceClient() just places the control in
an inactive state - it does not terminate it.
oleControlSiteObject.dispose() calls
oleControlSiteObject.deactivateInPlaceClient() and calls Release on any
COM interfaces it has aquired.
Releasing all the COM interface should be enough to terminate the process,
however, it is possible that some COM interfaces are not being fully
released (i.e. to a RefCount of 0). If you have created an OleAutomation
object, you must dispose it when done with it. If you have created a
Variant (or received a Variant in an event or method invocation) you need
to dispose the Variant.
Please provide an example to show the failure you are seeing.
"Christian Sauer" <christian.sauer@xxxxxxxxxxxxx>
Sent by: platform-swt-dev-admin@xxxxxxxxxxx
08/25/2003 04:51 AM
Please respond to platform-swt-dev
To: <platform-swt-dev@xxxxxxxxxxx>
cc:
Subject: [platform-swt-dev] How to stop an ActiveX Control
in SWT properly?
Hi all,
is it possible to explicitly end a win32 process which has been
started before by embedding an activeX control (e.g. Excel)?
calling 'oleControlSiteObject.dispose()' and
'oleControlSiteObject.deactivateInPlaceClient()'
does not end the process.
thanks for a hint,
chris
-------------------------------------------------------------------------
Giniality AG - Christian Sauer; Steinenberg 21, CH-4051 Basel
Phone: +41 61 226 99 66; Fax: +41 61 226 99 69;
E-Mail: xxx; WWW: http://www.giniality.com