Emilo:
   Sorry I should have mentioned.   I am running accumulo 1.9.3 and 
geomesa 3.0.0.
Thanks for the quick response.
On 7/30/2020 3:42 PM, Emilio Lahr-Vivaz wrote:
Hello,
I don't think that the converter is the issue - are you possibly on 
Accumulo 1.6? There appears to be an error checking the table 
namespace, which I believe was only added in 1.7 (which is the minimum 
supported version for GeoMesa). Otherwise, check your cluster logs, 
there should be more details on the error there.
Thanks,
Emilio
On 7/30/20 3:06 PM, David Boyd wrote:
All:
  I have a small issue.  My geomesa-accumulo is managed by puppet.  
So I can't edit
the baseline application.conf file in the ${GEOMESA_HOME}/conf dir.
I tried putting the converter definition and sft definition in files 
and referencing them from the command line.
But either I have the syntax/format wrong or something else.
Here is my command I am running:
[root@dspcnode11 jwacdata]# geomesa-accumulo ingest -z dspcnode01 -u 
xxxxx -p xxxxxxxxx -i dspc -c power -C tranlines.conf -f 
tranlines.conf transmission_lines/Transmission_Lines.shp
INFO  Creating schema 'transmission-lines'
ERROR org.apache.thrift.TApplicationException: Internal error 
processing checkNamespaceClass
org.apache.accumulo.core.client.AccumuloException: 
org.apache.thrift.TApplicationException: Internal error processing 
checkNamespaceClass
        at 
org.apache.accumulo.core.client.impl.NamespaceOperationsImpl.testClassLoad(NamespaceOperationsImpl.java:268)
        at 
org.locationtech.geomesa.accumulo.data.AccumuloDataStore.preSchemaCreate(AccumuloDataStore.scala:166)
        at 
org.locationtech.geomesa.index.geotools.MetadataBackedDataStore.createSchema(MetadataBackedDataStore.scala:136)
        at 
org.locationtech.geomesa.index.geotools.MetadataBackedDataStore.createSchema(MetadataBackedDataStore.scala:40)
        at 
org.locationtech.geomesa.tools.ingest.AbstractConverterIngest.run(AbstractConverterIngest.scala:31)
        at 
org.locationtech.geomesa.tools.ingest.IngestCommand$$anonfun$execute$2.apply(IngestCommand.scala:106)
        at 
org.locationtech.geomesa.tools.ingest.IngestCommand$$anonfun$execute$2.apply(IngestCommand.scala:105)
        at scala.Option.foreach(Option.scala:257)
        at 
org.locationtech.geomesa.tools.ingest.IngestCommand$class.execute(IngestCommand.scala:105)
        at 
org.locationtech.geomesa.accumulo.tools.ingest.AccumuloIngestCommand.execute(AccumuloIngestCommand.scala:24)
        at 
org.locationtech.geomesa.tools.Runner$class.main(Runner.scala:28)
        at 
org.locationtech.geomesa.accumulo.tools.AccumuloRunner$.main(AccumuloRunner.scala:19)
        at 
org.locationtech.geomesa.accumulo.tools.AccumuloRunner.main(AccumuloRunner.scala)
Caused by: org.apache.thrift.TApplicationException: Internal error 
processing checkNamespaceClass
        at 
org.apache.thrift.TApplicationException.read(TApplicationException.java:111)
        at 
org.apache.thrift.TServiceClient.receiveBase(TServiceClient.java:79)
        at 
org.apache.accumulo.core.client.impl.thrift.ClientService$Client.recv_checkNamespaceClass(ClientService.java:1022)
        at 
org.apache.accumulo.core.client.impl.thrift.ClientService$Client.checkNamespaceClass(ClientService.java:1005)
        at 
org.apache.accumulo.core.client.impl.NamespaceOperationsImpl$4.execute(NamespaceOperationsImpl.java:252)
        at 
org.apache.accumulo.core.client.impl.NamespaceOperationsImpl$4.execute(NamespaceOperationsImpl.java:249)
        at 
org.apache.accumulo.core.client.impl.ServerClient.executeRaw(ServerClient.java:83)
        at 
org.apache.accumulo.core.client.impl.NamespaceOperationsImpl.testClassLoad(NamespaceOperationsImpl.java:249)
        ... 12 more
Here is the sft file content:
    "transmission-lines" = {
      attributes = [
        { name = "fid",      type = "String",         index = false }
        { name = "inferred",     type = "String", index = true  }
        { name = "naics_code",      type = "String", index = true }
        { name = "naics_desc", type = "String", index = false }
        { name = "owner", type = "String",            index = true }
        { name = "shape_length", type = "Double", index = false }
        { name = "source", type = "String",            index = true }
        { name = "sourcedate", type = "Date",            index = true }
        { name = "status", type = "String",            index = true }
        { name = "sub_1", type = "String",            index = true }
        { name = "sub_2", type = "String",            index = true }
        { name = "type", type = "String",            index = true }
        { name = "val_date", type = "Date",            index = true }
        { name = "val_method", type = "String", index = true }
        { name = "volt_class", type = "String", index = true }
        { name = "voltage", type = "Double",            index = true }
        { name = "geom",     type = "LineString",      index = true, 
srid = 4326, default = true }
      ]
    }
  }
Here is the converter:
    "transmission-shp" = {
      type   = "shp"
      id-field   = "$0"
      fields = [
        { name = "inferred",      transform = 
"INFERRED"                     }
        { name = "naics_code",     transform = 
"NAICS_CODE"                  }
        { name = "naics_desc",      transform = 
"NAICS_DESC"                     }
        { name = "owner", transform = "OWNER"      }
        { name = "shape_length",      transform = 
"SHAPE_Leng"                  }
        { name = "source",      transform = "SOURCE"                  }
        { name = "sourcedate",      transform = 
"SOURCEDATE"                  }
        { name = "status",      transform = "STATUS"                  }
        { name = "sub_1",      transform = "SUB_1"                  }
        { name = "sub_2",      transform = "SUB_2"                  }
        { name = "type",      transform = "TYPE"                  }
        { name = "val_date",      transform = 
"VAL_DATE"                  }
        { name = "val_method",      transform = 
"VAL_METHOD"                  }
        { name = "volt_class",      transform = 
"VAL_CLASS"                  }
        { name = "voltage",      transform = 
"VOLTAGE"                  }
        { name = "geom",     transform = 
"multilinestring(the_geom)"              }
      ]
    }
_______________________________________________
geomesa-users mailing list
geomesa-users@xxxxxxxxxxx
To unsubscribe from this list, visit 
https://dev.eclipse.org/mailman/listinfo/geomesa-users
--
========= mailto:dboyd@xxxxxxxxxxxxxxxxx ============
David W. Boyd
VP,  Data Solutions
10432 Balls Ford, Suite 240
Manassas, VA 20109
office:   +1-703-552-2862
cell:     +1-703-402-7908
============== http://www.incadencecorp.com/ ============
ISO/IEC JTC1 SC42/WG2, editor ISO/IEC 20546, ISO/IEC 20547-1
Chair INCITS TG Big Data
Co-chair NIST Big Data Public Working Group Reference Architecture
First Robotic Mentor - FRC, FTC - www.iliterobotics.org
Board Member- USSTEM Foundation - www.usstem.org
The information contained in this message may be privileged
and/or confidential and protected from disclosure.
If the reader of this message is not the intended recipient
or an employee or agent responsible for delivering this message
to the intended recipient, you are hereby notified that any
dissemination, distribution or copying of this communication
is strictly prohibited.  If you have received this communication
in error, please notify the sender immediately by replying to
this message and deleting the material from any computer.